The SAP is the “Shift Actuating Panel” for the 7-speed DCT in Ferraris, Mercedes AMG GT and SLS, and the third generation Ford GT. This panel contains the hydraulic valve body that uses DCT clutch oil pressure from the Clutch Control Panel (CCP) to force the gear changes.

 

This is a brand new unit from Getrag containing all new solenoids, wiring harness (with updated abrasion resistant wire guard), sensors, and magnets (that interact with the shift position sensors).

 

Replacement of this panel resolves all faults related to the SAP (when referenced to the DCT Fault guide provided by Ferrari on the NHTSA website) IF the CCP is providing proper clutch fluid pressure to the SAP and the gear oil side of the transmission is assembled and functioning properly. If gear set is assembled incorrectly, if synchronizers have failed, if other mechanical items have failed in the gear oil side of the gearbox or if the CCP is not providing the proper oil pressure to the SAP, then replacing the SAP may not resolve your faults. Careful diagnostic procedures must be followed before purchase of this item as it is not returnable once used.

Secure
Delivery
30-Days
Return
Advanced
Discount System
Quantity

The SAP is the “Shift Actuating Panel” for the 7-speed DCT in Ferraris, Mercedes AMG GT and SLS, and the third generation Ford GT. This panel contains the hydraulic valve body that uses DCT clutch oil pressure from the Clutch Control Panel (CCP) to force the gear changes.

This is a brand new unit from Getrag containing all new solenoids, wiring harness (with updated abrasion resistant wire guard), sensors, and magnets (that interact with the shift position sensors).

Replacement of this panel resolves all faults related to the SAP (when referenced to the DCT Fault guide provided by Ferrari on the NHTSA website) IF the CCP is providing proper clutch fluid pressure to the SAP and the gear oil side of the transmission is assembled and functioning properly. If gear set is assembled incorrectly, if synchronizers have failed, if other mechanical items have failed in the gear oil side of the gearbox or if the CCP is not providing the proper oil pressure to the SAP, then replacing the SAP may not resolve your faults. Careful diagnostic procedures must be followed before purchase of this item as it is not returnable once used.

Fault codes this panel can resolve are as follows:
SAP P0751 Actuator A activate signal, too low Electric/mechanical fault in gear selector solenoid valve A. SAP P0752 Actuator A activate signal, too high Electric/mechanical fault in gear selector solenoid valve A. SAP P0753 Actuator A activate signal, no signal Electric/mechanical fault in gear selector solenoid valve A. SAP P0756 Actuator B activate signal, too low Electric/mechanical fault in gear selector solenoid valve B. SAP P0757 Actuator B activate signal, too high Electric/mechanical fault in gear selector solenoid valve B. SAP P0758 Actuator B activate signal, no signal Electric/mechanical fault in gear selector solenoid valve B. SAP P0761 Actuator C activate signal, too low Electric/mechanical fault in gear selector solenoid valve C. SAP DTC read on NCR Description of DTC Fault Component involved P0762 Actuator C activate signal, too high Electric/mechanical fault in gear selector solenoid valve C. SAP P0763 Actuator C activate signal, no signal Electric/mechanical fault in gear selector solenoid valve C. SAP P0766 Actuator D activate signal, too low Electric/mechanical fault in gear selector solenoid valve D. SAP P0767 Actuator D activate signal, too high Electric/mechanical fault in gear selector solenoid valve D. SAP P0768 Actuator D activate signal, no signal Electric/mechanical fault in gear selector solenoid valve D. SAP P0771 ODD/EVEN selector command signal, too low Electric/mechanical fault in gear selector solenoid valve E. SAP P0772 ODD/EVEN selector command signal, too high Electric/mechanical fault in gear selector solenoid valve E. SAP P0773 ODD/EVEN selector command signal, no signal Electric/mechanical fault in gear selector solenoid valve E. SAP, P0972 IN_ROD_POS_1, no signal Electrical fault in actuator 1 engage position sensor. SAP Technical Service Department Page 9 of 18 DTC read on NCR Description of DTC Fault Component involved P0973 Actuator 1 engage position sensor, too low Electrical fault in actuator 1 engage position sensor. SAP P0974 Actuator 1 engage position sensor, too high Electrical fault in actuator 1 engage position sensor. SAP P0975 IN_ROD_POS_2, no signal Electrical fault in actuator 2 engage position sensor. SAP P0976 Actuator 2 engage position sensor, too low Electrical fault in actuator 2 engage position sensor. SAP P0977 Actuator 2 engage position sensor, too high Electrical fault in actuator 2 engage position sensor. SAP P0978 Actuator 4 engage position sensor, no signal Electrical fault in actuator 4 engage position sensor. SAP P0979 Actuator 4 engage position sensor, too low Electrical fault in actuator 4 engage position sensor. SAP P0980 Actuator 4 engage position sensor, too high Electrical fault in actuator 4 engage position sensor. SAP P0981 IN_ROD_POS_3, no signal Electrical fault in selector actuator 3 position sensor. SAP. P0982 Actuator 3 engage position sensor, too low Electrical fault in selector actuator 3 position sensor. SAP. P0983 Actuator 3 engage position sensor, too high Electrical fault in selector actuator 3 position sensor. SAP. P0985 IN_SELECTOR_POS, too low Electrical fault in selector engage position sensor. SAP. P0986 IN_SELECTOR_POS, too high Electrical fault in selector engage position sensor. SAP. P1790 Parklock position – redundant sensor, too high Electrical fault in parklock position sensor. SAP. P1791 Parklock position – redundant sensor, too low Electrical fault in parklock position sensor. SAP DTC read on NCR Description of DTC Fault Component involved. P1795 Parklock position sensor, too high Electrical fault in parklock position sensor. SAP. P1796 Parklock position sensor, too low Electrical fault in parklock position sensor. SAP. P1800 Parklock hydraulic command signal, too low Electric/mechanical fault in parklock solenoid valve. SAP. P1801 Parklock hydraulic command signal, too high Electric/mechanical fault in parklock solenoid valve. SAP. P1802 Parklock hydraulic command signal, no signal Electric/mechanical fault in parklock solenoid valve. SAP. P1908 APP_ROD_MECH_ ODD, too high (odd gearbox shaft mechanical variation too frequent) Mechanical fault in RODs. SAP. P1909 APP_ROD_MECH_ ODD, no signal (odd gearbox shaft mechanical variation too long) Mechanical fault in RODs. SAP. P190B APP_ROD_MECH_ EVEN, too high (even gearbox shaft mechanical variation too frequent) Mechanical fault in RODs. SAP. P190C APP_ROD_MECH_ EVEN, no signal (even gearbox shaft mechanical variation too long) Mechanical fault in RODs. SAP., P1912 APP_ROD_POS_ODD, too high (position fault, odd shaft rod 1/3) Mechanical fault in RODs. SAP. P1913 APP_ROD_POS_ODD, no signal (position fault, odd shaft rods 1/3 and 5/7) Mechanical fault in RODs. SAP. P1914 APP_ROD_POS_EVEN, too high (position fault, even shaft rod 4/R) Mechanical fault in RODs. SAP. P1915 APP_ROD_POS_EVEN, no signal (position fault, odd shaft rods 2/6 and 4/R) Mechanical fault in RODs. SAP., P192A APP_SELECTOR_POS, too high (gearbox section selector, too high) Fault in SAP internal selectors. SAP. P192B APP_SELECTOR_POS, too low (gearbox section selector, too low) Fault in SAP internal selectors. SAP., P1952 L2_SG13_ILLEGAL_DISENGAGEM ENT_OF_PARKLOCK, invalid signal (illegal parklock disengagement) Electric/mechanical fault in Park lock ON/OFF solenoid valve. SAP. P1953 L2_SG14_PARKLOCK_IS_NOT_EN GAGING, invalid signal (parklock not engaging) Electric/mechanical fault in Park lock ON/OFF solenoid valve. SAP. P1954 L2_SG16_ILLEGAL_ENGAGEMEN T_OF_PARKLOCK invalid signal (illegal parklock engagement) Electric/mechanical fault in Park lock ON/OFF solenoid valve. SAP. Technical Service Department Page 12 of 18 DTC read on NCR Description of DTC Fault Component involved P1956 APP_ROD_POS_ODD, too low (position fault, odd shaft rod 5/7) Mechanical fault in RODs. SAP. P1957 APP_ROD_POS_EVEN, too low (position fault, even shaft rod 2/6) Mechanical fault in RODs. SAP. P1958 APP_SOLENOID_PAIR_AB, no signal (synchro solenoid valve A(311) stuck OFF) Fault in gear selection synchroniser. SAP. P1959 APP_SOLENOID_PAIR_AB, invalid signal (synchro solenoid valve B(312) stuck OFF) Fault in gear selection synchroniser. SAP. P195A APP_SOLENOID_PAIR_CD, no signal (synchro solenoid valve C(313) stuck OFF) Fault in gear selection synchroniser. SAP. P195B APP_SOLENOID_PAIR_CD, invalid signal (synchro solenoid valve D(314) stuck OFF) Fault in gear selection synchroniser. SAP. P195C APP_SOLENOID_PAIR_AB, too high (synchro solenoid valve A(311) stuck ON) Fault in gear selection synchroniser. SAP. P195D APP_SOLENOID_PAIR_AB, too low (synchro solenoid valve B(312) stuck ON) Fault in gear selection synchroniser. SAP. P195E APP_SOLENOID_PAIR_CD, too high (synchro solenoid valve C(313) stuck ON) Fault in gear selection synchroniser. SAP. P195F APP_SOLENOID_PAIR_CD, too low (synchro solenoid valve D(314) stuck ON) Fault in gear selection synchroniser. SAP. P1960 Ground loop 2 (hydraulic parklock – gear engagement actuators), too high (earth level of power line B too high) Wiring harness connecting gear selector actuators to ground is damaged or disconnected. SAP. P1961 Ground loop 2 (hydraulic parklock – gear engagement actuators), too low (earth level of power line B too low) Wiring harness connecting gear selector actuators to ground is damaged or disconnected. SAP. P1962 Ground loop 3 (hydraulic parklock – gear engagement actuators), too high (earth level of power line B too low) Wiring harness connecting gear selector actuators to ground is damaged or disconnected. SAP. DTC read on NCR Description of DTC Fault Component involved P1963 Ground loop 3 (hydraulic parklock – gear engagement actuators), too low (earth level of power line B too low) Wiring harness connecting gear selector actuators to ground is damaged or disconnected. SAP. P1964 sensor_REDUNDANT actuator 1 engage position sensor, too low (redundant engage position sensor A) Electrical fault in gear engage actuator position sensors. SAP. P1965 sensor_REDUNDANT actuator 1 engage position sensor, too high (redundant engage position sensor A) Electrical fault in gear engage actuator position sensors. SAP. P1966 sensor_REDUNDANT actuator 2 engage position sensor, too low (redundant engage position sensor B) Electrical fault in gear engage actuator position sensors. SAP. P1967 sensor_REDUNDANT actuator 2 engage position sensor, too high (redundant engage position sensor B) Electrical fault in gear engage actuator position sensors. SAP. P1968 sensor_REDUNDANT actuator 3 engage position sensor, too low (redundant engage position sensor C) Electrical fault in gear engage actuator position sensors. SAP. P1969 sensor_REDUNDANT actuator 3 engage position sensor, too high (redundant engage position sensor C) Electrical fault in gear engage actuator position sensors. SAP. P196A sensor_REDUNDANT actuator 4 engage position sensor, too low (redundant engage position sensor D) Electrical fault in gear engage actuator position sensors. SAP. P196B sensor_REDUNDANT actuator 4 engage position sensor, too high (redundant engage position sensor D) Electrical fault in gear engage actuator position sensors. SAP. P196C APP_PARKLOCK, invalid signal (parklock fault level high) Electrical fault in parklock position sensor. SAP. P1974 APP_SYNCHRO_1ST, too high (command fault, 1st gear does not arrive) Fault in gear selection synchroniser. SAP. P1975 APP_SYNCHRO_1ST, too low (command fault, 1st gear does not leave) Fault in gear selection synchroniser. SAP. Technical Service Department Page 13 of 18 DTC read on NCR Description of DTC Fault Component involved P1976 APP_SYNCHRO_1ST, no signal (command fault, 1st gear stuck) Fault in gear selection synchroniser. SAP. P1977 APP_SYNCHRO_2ND, too high (command fault, 2nd gear does not arrive) Fault in gear selection synchroniser. SAP. P1978 APP_SYNCHRO_2ND, too low (command fault, 2nd gear does not leave) Fault in gear selection synchroniser. SAP. P1979 APP_SYNCHRO_2ND, no signal (command fault, 2nd gear stuck) Fault in gear selection synchroniser. SAP. P197A APP_SYNCHRO_3RD, too high (command fault, 3rd gear does not arrive) Fault in gear selection synchroniser. SAP. P197B APP_SYNCHRO_3RD, too low (command fault, 3rd gear does not leave) Fault in gear selection synchroniser. SAP. P197C APP_SYNCHRO_3RD, no signal (command fault, 3rd gear stuck) Fault in gear selection synchroniser. SAP. P197D APP_SYNCHRO_4TH, too high (command fault, 4th gear does not arrive) Fault in gear selection synchroniser. SAP. P197E APP_SYNCHRO_4TH, too low (command fault, 4th gear does not leave) Fault in gear selection synchroniser. SAP. P197F APP_SYNCHRO_4TH, no signal (command fault, 4th gear stuck) Fault in gear selection synchroniser. SAP. P1980 APP_SYNCHRO_5TH, too high (command fault, 5th gear does not arrive) Fault in gear selection synchroniser. SAP. P1981 APP_SYNCHRO_5TH, too low (command fault, 5th gear does not leave) Fault in gear selection synchroniser. SAP. P1982 APP_SYNCHRO_5TH, no signal (command fault, 5th gear stuck) Fault in gear selection synchroniser. SAP. P1983 APP_SYNCHRO_6TH, too high (command fault, 6th gear does not arrive) Fault in gear selection synchroniser. SAP. P1984 APP_SYNCHRO_6TH, too low (command fault, 6th gear does not leave) Fault in gear selection synchroniser. SAP. DTC read on NCR Description of DTC Fault Component involved P1985 APP_SYNCHRO_6TH, no signal (command fault, 6th gear stuck) Fault in gear selection synchroniser. SAP. P1986 APP_SYNCHRO_7TH, too high (command fault, 7th gear does not arrive) Fault in gear selection synchroniser. SAP. P1987 APP_SYNCHRO_7TH, too low (command fault, 7th gear does not leave) Fault in gear selection synchroniser. SAP. P1988 APP_SYNCHRO_7TH, no signal (command fault, 7th gear stuck) Fault in gear selection synchroniser. SAP. P1989 APP_SYNCHRO_REV, too high (command fault, reverse does not arrive) Fault in gear selection synchroniser. SAP. P198A APP_SYNCHRO_REV, too low (command fault, reverse does not leave) Fault in gear selection synchroniser. SAP. P198B APP_SYNCHRO_REV, no signal (command fault, reverse stuck) Fault in gear selection synchroniser. SAP., P1991 APP_COMPLEMENT_ ROD_MOVE, too high (odd clutch additional rod movement fault) Mechanical fault in RODs. SAP. P1992 APP_COMPLEMENT_ ROD_MOVE, too low (even clutch additional rod movement fault) Mechanical fault in RODs. SAP.